I often get called out to slap up new ceiling lights customers have purchased from the likes of Homebase, B&Q, John Lewis and Argos, but simply hanging a new light is often not as easy as you might think...


It used to be the case that everyone had plain white plastic ceiling pendants and the introduction of a bit of colour or style into a room meant dangling your lampshade of choice from the thing, but these days there are all sorts of pretty looking light fittings which are designed to be fitted wholly in place of the existing pendant or rose. The trouble is, they’re often designed by people who don’t have to install them, are knocked out of Chinese factories for multinational delivery and they can be woefully inadequate for the British way of wiring protruding from your ceiling. Many a time I’ve come across DIY dad who, having been lumbered with the task of putting up the blingy new light, has climbed the step ladder, unscrewed the existing rose and found to his dismay that there are many more wires than he expected lurking within...

2015-07-06 15.37.03


At this point anyone not familiar with what they’re looking at should climb back down the ladder, put it away, fetch a cold one from the fridge and give someone like me a call, but sometimes perseverance sees through, sadly often unsuccessfully and with an end result where flicking the switch makes a loud bang in the fuse box, or suddenly other lights on the same floor are found to no longer be working.


This is all because in most pre-Noughties UK houses you’ll find the lighting is wired in a method called Three Plate, also known as Loop in. Instead of there just being a simple line, neutral and earth in the rose, there will be a L-N-E feed (loop) in, a feed (loop) out to the next light in the chain, and a cable going off to the switch for a line out and switched line return. Just to add to the confusion, on pre 2005 houses the neutrals will be black but the switched line may also be black and the line wiring will be red.... but the switched line may also be red. If modified or installed since 2005, you’ll see brown and blue instead of red and black, but again the switched line may be coloured either blue or brown depending on what mood the installer was in on the day and whether they bothered to use any colour coded sleeving to correctly identify the function of each conductor.

loopinloopout


What all this means is that not only will there be more wires than expected, but the same colours may be serving different functions so, if you don’t take note of what went where, you may find your new light won’t turn off, the breaker/fuse pops when you switch it on, it doesn’t operate at all or the lights in other rooms on the same circuit no longer function.


If replacing lighting in a cloakroom or bathroom, then there may be even more wires in there to service a fan. In that case you may see another cable which has three cores plus an earth, and these cores may be coloured red, yellow and blue (pre 2005), or brown, black and grey (post 2005). The red or brown would likely be a permanent line conductor, one of the others will be a switched line and the final conductor will be neutral. Although there are preferred combinations, which is what actually depends on the installer and careful note needs to be taken if they haven’t used colour coded sleeving to identify the function of each conductor.


But the manufacturers of stylish light fittings usually don’t care too much, so what we end up with is something ridiculous like this:

2015-06-04 15.00.48


Note the teeny tiny rose portion on this Homebase light fitting which is demonstrably not fit for purpose as a like-for-like replacement where three plate wiring is in use, i.e. in pretty much any home in the UK built before around 2010. Already there’s very little room in there with the lamp wiring, bracket and crappy connector block, and this luminaire has been designed just for a single cable to enter it leaving no room to accommodate all the wires that actually spew out from the ceiling. Even if I could shoehorn everything into there, Regulation 559.5.3.1 was introduced in 17th Edition Amendment 3 of the Wiring Regulations to state "The installation of through wiring in a luminaire is only permitted if the luminaire is designed for such wiring." This fixture is clearly not designed for anything other than a single feed cable. 


In the pictured example we’re in a bathroom so we have four cables, loop in, loop out, switch drop and the supply for a timed bathroom fan. We also have a mixture of wiring colours with older red/black and newer brown/blue cores indicating a mix of original and newer wiring, although at least the installer who put the new stuff in has used brown and blue sleeving to aid with core identification. The CPC’s (earths) are not sleeved in this picture and need to be, it’s just that earth sleeving has a bloody annoying habit of falling off when you’re at the top of a ladder.


Any botched attempt to get all this wiring to fit into that stupid little enclosure will be impossible to achieve professionally and may result in poor connections, reduced insulation resistance and nuisance tripping. The only fix for this mess is to pull all the wires back into the attic, properly junction them using a nice maintenance-free solution, then drop down the single cable that this fitting was designed for.


While that sounds like it shouldn’t be too taxing for a professional, it can take a long time to do properly, especially if access in the attic is poor or if it is boarded. If you have several lights you want installed and you're being charged by the hour instead of a fixed rate then the time can clock up. If this kind of situation is on the ground floor and there is no attic access above, then you may be scuppered as proper junctioning may require a larger hole in the ceiling just to get the junction enclosure stuffed up there, but that silly little rose base won’t cover the damage to the plasterboard so you're stuck with a filler repair/repainting job.


If you have a concrete ceiling as in some flats then forget it, there’s nowhere to lose the wires. You’ll simply *have* to purchase a luminaire that can accommodate all the wires and junctioning.


While we're at it, let's name and shame John Lewis after we came across two examples of their lighting wares which we had the misfortune to be asked to install this week...

johnlewis1


This is the kind of thing that boils my piss; we have a metal light fitting here but rather than admit to it being a Class I luminaire which requires an earth, they pretend it's Class II by installing the world's smallest connector block encased in plastic. The only cable this crappy connector can take is a two-core flex. So, what on earth is the installer to do with all the single insulated wires coming out of the ceiling? A bad installer or DIYer will leave them in the rose portion of the fitting which means it's no longer double-insulated and if the metalwork goes live there is no earth return path for safety. A good installer will be forced to either double-insulate all the cores and connections if there's room to safely accommodate them, or junction all wiring externally and to ensure only a two-core flex with two layers of insulation enters the rose. It's massively time consuming to install safely and properly and the customer doesn't expect it to be so labour intensive, and therefore expensive, because they figure it'll just be 'one-off, one-on' and how hard can it be anyway?

2017 03 09 09.22.03  

Above, another Class I John Lewis luminaire pretending to be Class II. If it's metal, don't pretend it doesn't need an earth! Presumably John Lewis do this so their blingy fittings can be installed in older homes where lighting circuits lacked earth wiring, but in reality thousands of these metal fittings end up improperly installed every year leaving a shock risk to anyone touching it to change a light bulb.

NotAmused


Also, what the hell is the story with this John Lewis abomination? Young Dior here is having to thread all of these silly plastic 'crystal effect' things around the light because it doesn't come pre-assembled. No wonder he looks so blimmin' miserable! Not only is this incredibly time consuming, but as it turned out some parts were missing in the box so now the customer is having to get extra bits sent out and we have to go back to complete the installation on another day. Gaa!


John Lewis charge a premium price for these luminaires, yet they come with halogen rather than LED lamps (very last century), require labour intensive electrical installation and significant on-site assembly.


If you’re looking at fancy new lights that have been built to look good while lacking in installation practicality, then be prepared to have to hire in a professional to install them. Also be prepared to have to pay for a job that may take much longer than you imagine because any professional sparkie worth his salt is going to have to perform some junctioning wizardry if those lights are going to work safely and properly in the long term.


And no, using screw blocks, wrapping them in tape and poking them into the ceiling hole is not an option. If you’ve hired a professional and you catch them doing that, ask them to pack up their tools and sod off.


Interesingly, or perhaps not, some bright spark has developed a solution to aid with this problem as reviewed on my YouTube channel below...

 

 